1 | PIR Ready VT76x7 Series-Installation Guide
CONTENTS
Installation 2
Location 2
Installation 2
Theory of operation 3
Features overview 4
Model Chart 5
Network ready 6
Terminal, Identification and Function 6
Wiring 6
Screw terminal arrangement 7
Typical applications 8
Remote humidity sensor accessories 9
Configuring and Status Display Instructions 10
Status display 10
User Interface 12
User configuring instructions menu 12
Local keypad interface 13
Occupied setpoints adjustments 14
Dehumidification process 16
Installer Configuration Parameter Menu 21
Troubleshooting guide 32
Humidity Control 34
Humidity reset 34
High limit humidity sensor 34
Specifications 35
Drawing & Dimensions 36
PIR Ready VT76x7 Series
With & Without Local Schedule &
With Humidification & Dehumidification
Strategy Terminal Equipment Controllers
Installation Guide
For Commercial HVAC Applications
May 3
rd
, 2012 / 028-0229-R4
April 26, 2011 / 028-0190-R6
May 5, 2011 / 028-0228-R3
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Installation Guide

1 | PIR Ready VT76x7 Series-Installation Guide CONTENTS Installation 2 Location 2 Installation 2 Theory of operation 3 Features overview 4

Page 2 - INSTALLATION

10 | PIR Ready VT76x7 Series-Installation Guide User menu flow chart: NOTE: Prompts may not all be present depending on model selected Sc h e du l

Page 3 - THEORY OF OPERATION

11 | PIR Ready VT76x7 Series-Installation Guide Sequence of auto-scroll status display: ROOM TEMP & RH CLOCK STATUS SYSTEM MODE SCHEDULE STATUS

Page 4 - Features overview

12 | PIR Ready VT76x7 Series-Installation Guide Three status LEDs on the Terminal Equipment Controller cover are used to indicate the status of the f

Page 5 - MODEL CHART

13 | PIR Ready VT76x7 Series-Installation Guide Local keypad interface Each of the sections in the menu is accessed and configured using 5 keys on t

Page 6 - Wiring

14 | PIR Ready VT76x7 Series-Installation Guide Occupied setpoints adjustments There is a default profile set in the Terminal Equipment Controller fr

Page 7 - Screw terminal arrangement

15 | PIR Ready VT76x7 Series-Installation Guide C) Temperature setpoints Permanent setpoint changes Temperat set Y/N This menu permits the ad

Page 8 - TYPICAL APPLICATIONS

16 | PIR Ready VT76x7 Series-Installation Guide 50% RH and the dehumidification setpoint is changed from 70% RH to 45% RH, the humidification setpoin

Page 9

17 | PIR Ready VT76x7 Series-Installation Guide E) System mode setting Sys mode set Y/N This menu is accessed to set system mode operation Use ▲

Page 10 - Status display

18 | PIR Ready VT76x7 Series-Installation Guide Monday timer Schedule set Tuesday timer Schedule set Wednesday timer Schedule set Other days are ide

Page 11

19 | PIR Ready VT76x7 Series-Installation Guide ** To schedule a day as occupied for 24 hours, set that day Occupied time to 12:00 AM and Unoccupied

Page 12 - USER INTERFACE

2 | PIR Ready VT76x7 Series-Installation Guide INSTALLATION Remove the security screw on the bottom of Terminal Equipment Controller cover.  Op

Page 13 - Local keypad interface

20 | PIR Ready VT76x7 Series-Installation Guide * Scheduling events to the same time will cancel the last period and leave the Terminal Equipment Con

Page 14

21 | PIR Ready VT76x7 Series-Installation Guide  Enabling a permanent occupied or permanent unoccupied schedule hold will cancel any active overrid

Page 15

22 | PIR Ready VT76x7 Series-Installation Guide CONFIGURATION PARAMETERS DEFAULT VALUE SIGNIFICANCE AND ADJUSTMENTS PswrdSet Configuration parameter

Page 16 - Dehumidification process

23 | PIR Ready VT76x7 Series-Installation Guide Channel Channel selection Default value = 10 Range is: 10 to 26 Conditional parameter to Wireless mo

Page 17

24 | PIR Ready VT76x7 Series-Installation Guide DI 1 Digital input no.1 configuration Open contact input = function not energized Closed contact inpu

Page 18

25 | PIR Ready VT76x7 Series-Installation Guide Lockout Keypad lockout levels Default value = 0 No lock 0 = No lock 1 = Low level 2 = High level USER

Page 19

26 | PIR Ready VT76x7 Series-Installation Guide Pband Proportional Band setting Default value 2 = 2.0 °F ( 0.6 °C ) Adjust the proportional band used

Page 20

27 | PIR Ready VT76x7 Series-Installation Guide Heat cph Heating stages cycles per hour Default value = 4 C.P.H. Will set the maximum number of heat

Page 21

28 | PIR Ready VT76x7 Series-Installation Guide TOccTime Default value = 3 hours Temporary occupancy time with occupied mode setpoints when override

Page 22

29 | PIR Ready VT76x7 Series-Installation Guide C stage Number of cooling stages 2 stages model only Default value = 2 stages Will revert the op

Page 23

3 | PIR Ready VT76x7 Series-Installation Guide 11. Gently push excess wiring back into hole (fig. 3). 12. Re-Install wiring terminals in their corr

Page 24

30 | PIR Ready VT76x7 Series-Installation Guide RH LT Reset RH lower outside temperature setpoint Default value = -20°F (-29°C) Minimum outsi

Page 25

31 | PIR Ready VT76x7 Series-Installation Guide RH HT Reset RH higher outside temperature setpoint Default value = 32°F (0°C) Maximum outdoor air tem

Page 26

32 | PIR Ready VT76x7 Series-Installation Guide RE SP Reset humidity setpoint Default value = 20% RH The RH setpoint will be reset from the user setp

Page 27

33 | PIR Ready VT76x7 Series-Installation Guide Terminal Equipment Controller will not call for heating Wrong mode selected Select heating mode Termi

Page 28

34 | PIR Ready VT76x7 Series-Installation Guide HUMIDITY CONTROL Humidity reset Humidity setpoint reset by outside air temperature If an outdoor

Page 29

35 | PIR Ready VT76x7 Series-Installation Guide SPECIFICATIONS Terminal Equipment Controller power requirements: Operating conditions: Storage co

Page 30

36 | PIR Ready VT76x7 Series-Installation Guide DRAWING & DIMENSIONS Viconics Technologies Inc. Tel.: Fax: Toll free:www.viconics.com

Page 31

4 | PIR Ready VT76x7 Series-Installation Guide Features overview  7 day schedule models, 2 or 4 events  Gas/oil or electric system compatibility

Page 32 - TROUBLESHOOTING GUIDE

5 | PIR Ready VT76x7 Series-Installation Guide MODEL CHART

Page 33

6 | PIR Ready VT76x7 Series-Installation Guide Network ready  All Viconics VT76x7 series Terminal Equipment Controllers are designed for stand-alon

Page 34 - HUMIDITY CONTROL

7 | PIR Ready VT76x7 Series-Installation Guide Screw terminal arrangement Wiring notes: Note 1: If the same power source is used for the heating

Page 35 - SPECIFICATIONS

8 | PIR Ready VT76x7 Series-Installation Guide TYPICAL APPLICATIONS

Page 36 - DRAWING & DIMENSIONS

9 | PIR Ready VT76x7 Series-Installation Guide Remote humidity sensor accessories Model no. Description VH2020W1000 Wall mounted humidity sensor VH2